3.2 System Grouping

Of  course,  the  system  is  also  grounded  via  the  power  supply  network  (thanks  to  the
protective  earth  conductor  –  if  this  is  connected  to  the  outlet).  However,  such
grounding  is  not  considered  sufficient  –  with  regard  to  the  danger  resulting  from  the
fact  that  the  system  may  easily  be  disconnected  from  the  power  supply  network
(over–voltage stemming from any line may thus easily be spread to the system chassis
and from there to any other line!).

ATTENTION!
The system should thus optimally be connected from the main
switchboard through a yellow–green conductor with a diameter of not
less than 4mm2 to the grounding ledge. In case of emergency the
"earth" should be connected by such conductor (i.e.
non–disconnectedly) to at least the closest power supply outlet (make
sure that the outlet is connected correctly).
The conductor should be attached to the system using the earthed
connector (on the backside of the system panel, marked with the
grounding symbol) that is to be fixed properly. The grounding should
be connected prior to the connection of any other wiring!!!

    