{Dimmer Feedback} - appears when the current address is patched to a dimmer in an ETC Sensor
rack with a CEM+ or CEM3. Sensor feedback must be enabled. See

Enable Sensor/ FDX3000

Feedback, page 248

and

Errors and Warnings, page 75

for more information.

{Dimmer Feedback} displays the following information:

•

Name (dimmer name)

•

Module type

•

Rack/Position

•

Rack dimmer level (displayed as a percentage)

•

Rack dimmer source

•

Recorded load

•

Actual load

{Dimmer Feedback} displays the following information, which can be modified from Element by
clicking on the value and entering in a new value:

•

Firing Mode

•

Control Mode

•

Curve

•

Threshold

•

Scale Minimum

•

Scale Maximum

•

Preheat Enable

•

Preheat Timing

•

Advanced Features (AF) Enable

Element supports the following softkey commands from this display:

•

{Ignore Errors}

•

{Clear Errors}

N o t e :

For Sensor feedback, the CEM+ must be running software version 3.0 or later.

N o t e :

Clearing CEM+ / CEM3 errors from Element will be temporary unless the errors

have been fixed at the CEM+ / CEM3 Errors displayed on Element will clear on

their own once they have been cleared from the CEM+ / CEM3. Some CEM+ /

CEM3 errors can only be cleared at the CEM+ / CEM3.