OPERATING INSTRUCTIONS

Roseville, MN

Ph: 1-800-444-2373

Fax: 651-645-7390

www.fastestinc.com

WP128 Rev A 05/01/2014

Installation:

Connect hose/fitting securely to the termination port of the connector.
1/8” NPT tighten to a maximum torque of 12 ft-lbs.
1/4

” NPT tighten to a maximum torque of 25 ft-lbs


Operation:

Connecting Action:

1.

Depending on the bore size the seals may need to be preloaded to
properly fit and seal the bore after handle has been rotated. To pre-load
prior to insertion into bore, spin washer cap with the handle in this
horizontal position and it will compress the main seal(s).







2. Insert sealing end into port and rotate handle 90° degrees.











CAUTION: The maximum rated pressure is stamped on the connector body. Be-
fore using, verify that this pressure rating is within your working pressures.

WARNING: Tug on the connector to assure proper engagement and gripping
before introduction of pressurized media.

DO NOT force connector onto test part when connecting. Forcing the connector
will result in poor sealing and possible leakage.

DO NOT spin test piece on seal once lever has been rotated 90° degrees.

3. Activate test media through connector termination port.

Disconnecting Action:

1. Deactivate test pressure. (DO NOT ROTATE LEVER UNTIL TEST

PRESSURE HAS BEEN DEACTIVATED).

2. Rotate lever to the horizontal position and remove from test piece.








Pressure Ratings:

1. When testing, maximum test pressure is 500psi.

Test Piece

Test Piece Inserted

TERMINATION

PORT

Washer Cap