COMMISSIONING

Testing & Adjustments

Fittings and pipe connections: Check all pipe fi ttings and
connections to the appliance for leaks. Use only approved
gas leak detectors or soap solutions to check fi tting and pipe
connections. DO NOT USE A FLAME.

1. Turn all valves and thermostats to the OFF position.

2. Turn on the main gas supply valve and light the top

section pilots.

3. Leak test the valves and fi ttings as described above, seal

any leaks found and re-check to make sure the leak is
sealed.

4. Light the oven pilot.

5. If the range is provided with an oven shut-off valve

separate from the thermostat, turn this valve ON and set
the thermostat at 250°C. Gas will now fl ow to the oven
burner.

6. Leak test all valves and fi ttings, seal leaks and re-test.

7. Shut OFF all range valves and set the thermostat dials to

the OFF position.

Pressure Settings (All Models Except Fryers)

1. Make sure all gas taps are in the OFF position and turn on

the main gas supply.

2. Light all pilots in accordance with the User’s Instructions.

3. Connect a U-gauge manometer to the pressure test point

on the main manifold and turn all gas controls to the ON
or position.

4. Confi rm that the pressure is the same as stated on the

rating plate.

Pressure Settings - Fryers

1. Connect a U-Gauge manometer to the pressure test point

at the end of the burner manifold and check that the
pressure setting is the same as stated on the rating plate.

2. If necessary, adjust the pressure using a screw driver to

turn the adjusting screw on the gas control. Turn the
control clockwise to increase pressure and counter-
clockwise to decrease.

Burner Adjustments

Check that the air shutter is set to the required opening.
Refer to Table H

Figure 1 – Air Shutter

Injector Location

Fixing Screw

Required Length

of Opening

Thermostat Bypass Adjustment - Oven

Figure 2 – Oven Thermostat

450 50

0

5

5

0

1

5

0

3

00

2

50

30

0

3

5

0

4

00

Calibration
Lock Screws

By-pass Flame
Adjuster

Indicator Mark

Calibration

Plate

Dial

Stop

With reference to Figure 2, the Robertshaw FDO snap-
throttle thermostat requires a bypass adjustment. To adjust
the bypass, follow this procedure.

1. Turn the oven temperature control dial to 200°F (93°C)

then allow the oven to heat for 3 minutes.

2. Turn the oven control dial to the OFF position, then

slowly turn the oven temperature control dial counter-
clockwise until an audible click is heard.

3. Making sure not to disturb the oven temperature control

dial, turn the bypass fl ame adjusting screw and adjust the
bypass fl ame to the LOWEST POSSIBLE STABLE FLAME
COVERING THE ENTIRE PORTED AREA OF THE BURNER.
Turn the adjusting screw counter-clockwise to increase or
clockwise to decrease the size of the bypass fl ame.