Servicing continued, Fryer – Garland MASTER SERIES HEAVY DUTY RANGES, FRYERS & BROILERS User Manual

Page 27

Advertising
background image

Part # 4519069 Rev 01(7 Feb 14)

Page 27

1. Place the thermocouple of the test instrument in the

center of the oven.

2. Light the oven, set the thermostat to 400°F (204°C) and

wait 15 minutes for the oven temperature to stabilize.

3. Check the temperature at 5 minute intervals until three

successive readings are within ±5°F (±3°C) of each other.

4. If the temperature is not within ±20°F (±8°C) of the

thermostat dial setting, refer to Figure 10 to recalibrate
using this procedure.

Figure 10 – Oven thermostat

450 50

0

5

5

0

1

5

0

3

00

2

50

30

0

3

5

0

4

00

Calibration
Lock Screws

By-pass Flame
Adjuster

Indicator Mark

Calibration

Plate

Dial

Stop

SERVICING continued

6. Remove the thermostat dial, making sure not to disturb

the setting.

7. Hold the calibration plate and loosen the two calibration

locking screws.

8. Turn the calibration plate counter – clockwise to increase

the oven temperature or clockwise to decrease it.

NOTE: One division of the calibration plate is equal to 25°F
(14°C).

9. Hold the plate and tighten the screws.

10. Replace the thermostat dial.

11. Recheck the calibration as specifi ed in this procedure to

confi rm that the correct adjustment has been made.

Fryer

The same observation made about oven thermostats applies
to fryers. That is, recalibration of the thermostat is seldom
necessary. If experience with the cooking results proves that
the temperature at which the dial is set is incorrect, follow
this procedure to re-calibrate the thermostat. Use a reliable
thermometer only or, preferably, a pyrometer.

1. Suspend the thermometer or thermocouple in the

middle of the fry tank about 2” (76mm) below top level of
oil.

2. Allow the burner to cycle four times.

3. When the burner cycles OFF after the fourth cycle,

compare the reading of the thermometer or
thermocouple with the thermostat setting.

4 If the two readings are not within ±5°F (±3°C) of one

another, loosen the two set screws in the thermostat
knob and set the pointer of the thermostat to agree with
the reading of the test thermometer or thermocouple.

5. Tighten the set screws on the thermostat knob after

resetting the pointer.