Commissioning continued, Operation – Garland MASTER SERIES HEAVY DUTY RANGES, FRYERS & BROILERS User Manual

Page 18

Advertising
background image

Part # 4519069 Rev 01(7 Feb 14)

Page 18

Solid Hot Plate/Griddle

1. Light the pilot light in accordance with the User’s

Instructions.

2. Check that the length of the fl ame is 12mm aprox and

adjust as necessary (see Figure 7).

Front Fired Hot Top

1. Light the pilot light in accordance with the User’s

Instructions.

2. Check that the length of the fl ame is 12mm and adjust as

necessary (see Figure 5).

Broiler

1. Light the pilot light in accordance with the User’s

Instructions.

2. Check that the length of the fl ame is 12mm and adjust as

necessary (see Figure 7).

COMMISSIONING continued

Fryer

1 Light the pilot light in accordance with the User’s

Instructions.

2. Check that the length of the fl ame is approximately

12mm and adjust as necessary.

When all the settings have been checked:

1. Remove the U-gauge manometer, replace the pressure

test point screw, the valve panel, oven base plate and the
lower kick panel.

2. Tell the user the location of the gas isolation cock for use

in an emergency.

3. Instruct the owner or user of the equipment in the

effi

cient and safe operation of the appliance.

OPERATION

This section deals with equipment operating instructions.
To fi nd the operating instructions for a particular piece of
equipment, consult the Table of contents.

Open Top Burners (MST Models)

1 Push in the gas valve and turn it counter-clockwise to the

ignition position.

2. Holding the valve fully in, light the pilot burner.

3. When the pilot burner is lit, continue holding the valve

fully in for 20 seconds, then release it. If the pilot goes out,
wait for fi ve minutes, then repeat the start procedure.

4. When the pilot is established, push the valve in again and

turn it counter-clockwise to the desired fl ame setting.

5. To shut off the burner, turn the dial to the ‘0’ position and

the safety device will disengage within 60 seconds.

Hot Top And Spectro-top Sections
(MST Models)

1 Push in the valve and turn it counter-clockwise to the

IGNITION position.

2. Holding the valve fully in, light the pilot burner.

3. When the pilot burner is lit, continue holding the valve

fully in for 20 seconds, then release it. If the pilot goes out,
wait for fi ve minutes, then repeat the start procedure.

4. When the pilot is established, push the valve in again and

turn it counter-clockwise to the desired fl ame setting.

5. To shut off the burner, turn the dial to the ‘0’ position and

the safety device will disengage within 60 seconds.