Installation

Garland RTCSmp Induction Built-in Griddles

12

Part # 4532291 Rev 2 (01/15/14)

Template for Holes and Studs:


C.
Four (4)
welding bolts

D. Opening for
service interface

E.
Holes for
mounting control
switch

To install a control unit:

1. Use the dimensions from the template above to install studs and create cut-outs on the cabinet.

2. The plastic knob is pressure fitted to the switch. Remove knob and fasten (fasteners not provided) the

unit to the back of the panel.

3. Mount the switch to the panel using two M4 screws (see illustration above). This prevents the

switch from rotating.

4. Apply overlay (provided) to the front of the panel and install knob.

Overall dimensions of the overlay: approx. 13.31”x 2.83” (338 x 72mm).

4.5.2 Built-In Griddle Plate Installation

There are two methods to install the built-in griddle unit—Drop-In or flush-mount. The counter surface cut-out
dimensions are different for these two methods.

4.5.2.1 Dimensions of RTCSmp Built-In GI-SH/GR/IN 3500 and 5000

(measurements in mm and [inch])