5 operating conditions, 6 compliances – Garland SHGRIN5000 INDUCTION BUILT-IN GRIDDLES User Manual

Page 8

Advertising
background image

Dimensions and Technical Specifications

Garland RTCSmp Induction Built-in Griddles

8

Part # 4532291 Rev 2 (01/15/14)

3.5 Operating Conditions

Max. Tolerance of Nominal Supply Voltage

+6 /-10 %

Supply frequency

50/60 Hz

Ingress Protection class

IP X0

Maximum Ambient Temperature

In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)

Maximum Relative Air Humidity

In Storage > 10% to 90%
In Operation > 30% to 90%

Maximum fan air flow: 88.29cfm/150m

3

per hour and min. opening: 16.59in

2

/10700mm

2

is required.

3.6 Compliances

North American models:

ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001

CE models

comply with the latest European Norms:

EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)

Patents:

Europatent EP 0858722, Swiss patent 695817, US 7183525 B2