Fit the cable through the machine.

Hold back the measuring
wheel, so that the spring is
compressed.

Raise the clear cover to
expose the roller drive.

Loosen the thumb nuts and re-
tract the cable guide top plate.

Loosen the thumb
nut and open the
seal housing.

Move the drive roller close
assembly to the far right to
fully open the rollers.

It is now possible to insert the cable in the machine.
Pass the cable through the tube in the in-feed guide clamp, on through the in-feed guide as-
sembly and through the gap between the drive rollers. Place the cable in the groove in the ca-
ble guide set. Select the appropriate split cable seal (see appendix 1) and position it around
the cable. Press the cable seal into the groove in the seal housing, simultaneously placing the
cable in the seal guide half and insert the cable in the tube entry.

The cable is now positioned in the machine.