General Machine Products Co., Inc.

(It will be necessary to adjust the position of the roller. This roller provides support for the
measuring wheel. It should be positioned so that the measuring wheel does not deflect the
cable.

9. Procedure for changing inserts in the in-feed guide

Loosen and remove the two screws
securing the upper housing onto the
lower housing

Loosen and remove the screw se-
curing the insert into the upper
housing

Remove the insert

Repeat the process for
the insert in the other
housing half

To fit the new inserts, reverse
the disassembly procedure.

10. Procedure for re-positioning the measuring system fixed roller

Loosen the screw holding the roller
support bracket in position

Position the bracket so that the roller is
in light contact with the new cable.
Tighten the screw.