12. Procedure for changing the seal guide halves

13. Procedure for changing the drive rollers

The machine is fitted with standard rollers, Tests have shown that these rollers give a good
compromise of life and grip. There may be circumstances when a roller with much higher grip
will be needed. If, for instance it is necessary to install a cable which will sustain crushing
damage when light compression forces are applied to it. It will be necessary to use a roller
with a surface coating with high friction characteristics. This will allow the cable to be pushed
with high torque while being compressed lightly. If this type of roller is needed, the GMP sales
office will be able to advise on part numbers etc. To install this roller it will be necessary to re-
move the standard roller, with the procedure as follows.

Loosen and remove the retaining
screw and washer

Remove the roller

Repeat

the procedure for the other roller

To fit the new rollers, reverse the assembly procedure

Loosen and remove the two retaining
screws. (Do not mislay these screws, they
will be needed for the new seal guide half)

Remove the seal guide half

Repeat the procedure for seal guide half in
the other housing half

To install the new guides, reverse the dis-
assembly procedure

Advertising