General Machine Products Co., Inc.

The device must be wired and installed into the machine prior to programming.

Tornado is fitted with C-M-DEV-CUB5R, reflective version

The DIP switch positions are as follows:

1 OFF
2 OFF
3 OFF
4 OFF

Please see the attached CUB5 Programming Overview attached to this
document.

• Press and hold SEL for 2 seconds to enter programming mode
• Enter the Pro-Code 222 by pressing RST to change numbers and SEL to skip

to the next number.

• Once correct Press and Hold SEL for 2 seconds
• Pro-no should now be flashing, press RST
• Press RST to move through the various sections 1-input, 2-rate 3-display,

sections 4 and 5 will be unavailable, see the next page of instructions for the
parameters required.

• Press SEL to enter that section
• To change the value of a parameter press RST
• Press SEL to move to the next parameter (You will have to hold for 2 seconds

on certain parameters).

• When all the parameters in the section have been scrolled through you will

return to the Pro-no display, press RST to scroll to another section else press
SEL to exit programming mode.

Programming Parameters for CUB5R Counter/rate Meter

Serial Numbers 0315 Onwards