General Machine Products 89000 Cable Blowing Machine(Previous) User Manual

Page 58

Advertising
background image

Page 58 of 64

General Machine Products Co., Inc.

First reset the current settings to Factory Settings on the counter:

Scroll to 3-DSPLAY

Skip through the parameters until FACT SET is displayed.
Change this to YES by pressing RST
PRO NO should be displayed, Press SEL.

Continue to re-program the Counter by pressing and holding SEL to re-enter
programming mode. Pro-no will be displayed, press RST to move through the relevant
sections. The following parameters are required for the Tornado counter:

Press RST Once:

Counter Parameters (1-INPUT)

INPA-B = Cnt ud - if correct press SEL.
CNT A DP = 0 - if correct press SEL.
CNT A SCF = 0.01 (Metric, m) or 0.0328 (Imperial, ft) - once

correct press & Hold SEL.

CNT A RST = TO ZERO - if correct press SEL.
CNT A DIR = NOR - if correct press SEL.
CNT B LD = 0 - once correct press & Hold SEL.
CNT B BAT = NO - if correct press SEL.
RST P-UP = NO - if correct press SEL.
USER INP = NO - if correct press SEL.

Press RST Twice:

Rate Parameters (2-RATE)

RATE ENB = YES - if correct press SEL.
RATE DP = 0 - if correct press SEL.
RATE DSP = 60 - once correct press & Hold SEL.
RATE INP = 100 (Metric, m/min) or 30.5 (Imperial, ft/min)-

once correct press & Hold SEL.

LO-UDT = 1.0 - if correct press SEL.
HI-UDT = 2.0 - if correct press SEL.

Press RST Three times:

DISPLAY (3-DSPLAY)

SEL ENB = YES - if correct press SEL.
RST ENB = YES - if correct press SEL.
D-SCROLL = NO - if correct press SEL.
PRO CODE = 222 - CODE REQUIRED TO RE-PROGRAM -

once correct press & Hold SEL.

FACT SET = NO - Press SEL Twice