INFICON CI-100 Crucible Indexer User Manual
Page 32
3 - 4
IP
N 07
4-
54
4-
P1
A
CI-100 Crucible Indexer Operating Manual
6: RS-232 communications (off)
NOTE: CI-100 does not support Ethernet communications.
7: Bit decode selection for BCD I/O Mode – see
.
8: Unused.
BCD I/O Connector
The pocket is selected using BCD encoded inputs. Same function and pinout
as MDC/Sycon indexers. See
for pinout and compatibility
instructions.
NOTE: Option switch 5 must be on (up) to use this connector.
Binary I/O Connector
The pocket is selected by individual inputs. Same function and pinout as
Telemark indexers. See
for pinout and compatibility instructions.
NOTE: Option switch 5 must be off (down) to use this connector.
RS-232/LAN Connector
Connector for RS-232 communications. See
for pinout.
NOTE: CI-100 does not support Ethernet communications.
Motor Connector
Provides power and control signals to the indexer motor. See
for
pinout.
Power Input
Connects to mains power. The CI-100 automatically detects mains voltages of
100-120 and 200-240 V (ac), 50/60 Hz.
WARNING
For continued protection, replace fuses with the proper
type and rating.
WARNING
Use removable power cords only of the specified type
and rating, attached to a properly grounded receptacle.