4 s-analog sensor object, 1 class attributes 4.4.2 semantics, 3 instance attributes – INFICON SKY CDGxxxD (DeviceNet) User Manual

Page 19

Advertising
background image

tira51e1 (2009-01) CDGxxxD.cp

19

Class Code 31

h

= 49

d


Attribute ID Access

rule

Name

DeviceNet
data type

Description of attribute

Semantics of values

1

Get

Revision

UINT

Revision of this object Note: All class definitions are
required to include this class attribute.

The current value
assigned to this attrib-
ute is one (01).

2 Get

Max
instance

UINT

Maximum instance number of an object currently
created in this class level of the device.

The largest Instance
number of a created
object at this class
hierarchy level.

94 Get

Active
value

INT or
specified by
data type

Is used by assemblies to produce this class-level
attribute, instead of the value (attribute ID 6) of the
S-Analog sensor instances.

95 Get

Active
instance
number

UINT

Identifies the object instance that is providing the
value which is copied into the active value for all
input assemblies and the alarm/warning exception
details for the S-Device supervisor object.
→ Behavior section.

Default = 1

96 Get

Number

of

gauges

USINT

Identifies the number of gauge instances present in
the device.

99

Get

Subclass

UINT

Identifies a subset of additional class attributes,
services and behaviors.

1

Instance selector



Assemblies or connections may produce this class-level attribute, instead of the
value (attribute ID 6) of the active S-Analog sensor instance. The S-Analog sensor
class-level attribute active instance number identifies the object instance that is
currently active and providing the value to the active value class-level attribute
which is, in turn, produced by the input assemblies that have active value as a
member.

The device internally modifies this attribute, as required, to identify the S-Analog
sensor object instance providing the value member which is copied into the active
value for all input assemblies and the alarm/warning exception details for the
S-Device supervisor object.
→ Behavior for more information on the mechanism.

This attribute is used to determine the size of all input assemblies within a node.
→ respective device profile for its usage within a device type.


Two S-Analog sensor instances (instance 1 and instance 2) are available. Instance
1 represents the physical sensor reading of the capacitance diaphragm gauge.
Instance 2 represents the physical sensor reading of the atmosphere pressure
sensor.

4.4 S-Analog Sensor Object

4.4.1 Class Attributes

4.4.2 Semantics

Active value

Active instance number

Number of gauges

4.4.3 Instance Attributes

Advertising