Horizontal left through top (see fig. 15), Exhaus t, 359aa v – Bryant 4-WAY MULTIPOISE 359AAV User Manual

Page 23

Advertising
background image

23

Trap Connection

“Clamp ears”
Pointed OUT

Preassemble &
insert into furnace

AIR

FLO

W

IN

ON

OF

F

V

E

N

T

Relief Tube
Black Rubber

3

/

16

ID

Plastic Caps
Yellow or black

Vent Drain
& Clamps

Single Pressure Switch Detail

Dual Pressure Switch

Tee Trap White PVC
(loose parts bag)

Cap and Clamp
Open End

Flexible Tubing Connector

3

/

16

OD (Loose Parts Bag)

Drain Tube
Black Rubber

1

/

2

ID & Clamps

EXHAUS

T

Alternate Orientation

Field
Supplied Tee

Cut Here

Drain Tube Corrugated

5

/

8

ID & Clamps

Cut at straight section

Leave room for clamp

Relief Tube Extension
Black Rubber

3

/

16

ID

Cut to Fit (Loose Parts Bag)

AIR

FL

OW

Coupling & Clamps
(Optional)

Representative drawing only, some models may vary in appearance.

Remove KO before
mounting Trap

A07709

Fig. 15 -- Horizontal Left through Top

Horizontal Left through Top (See Fig. 15)

S

Disconnect the hoses from the trap assembly, and remove trap
and trap mounting bracket from the blower compartment.
Using cover plate and gasket provided in the loose parts bag,
cover the hole from the burner compartment to the blower
compartment and secure with screws.

S

Remove knockout from the side of the furnace casing where
drain tube will exit.

S

Mount the trap externally to the bottom side of the unit using
the 2 screws provided in the location shown.

S

Cut the corrugated tube as shown in the illustration above.
Connect the corrugated hose from the transition to the trap.
Secure connections with clamps.

S

Remove the black

1

/

2

″(13 mm) ID drain tube from the drain

tee. Install a yellow cap and clamp over the open drain port of
the drain tee.

S

Connect the black

1

/

2

″(13 mm) ID drain tube from the Vent

Drain to the trap. Secure connections with clamps.

S

Connect the

3

/

16

″(5 mm) ID relief tube to the middle port on

the trap. If an extension is required, use the

3

/

16

″(5 mm) OD

flexible tubing connector and the black

3

/

16

″(5 mm) ID relief

tube in the loose parts bag. Cut tube to length. Secure all
connections with clamps.

S

Cut an appropriate length of 2″ (51 mm) PVC pipe, long
enough to exit the cabinet and connect the vent drain to either:

— A standard field supplied 2″ (51 mm) PVC tee, or
— A 2″ (51 mm) PVC coupling fastened onto the drain

tee.

S

Install tee trap into bottom section of tee.

S

Connect the tee trap and the main drain line exiting the casing
as shown in Fig. 19.

NOTE: It is recommended that all PVC piping and fitting
connections be fit up and inspected before final cementing. Both
the external trap and the external tee trap must be primed
before operation.
Verify all condensate drain connections are
securely clamped. A coupling and clamps (in loose part bag) may
be installed as shown for future servicing of the vent system.

359AA