Caution, Warning, Frozen water pipe hazard – Bryant 4-WAY MULTIPOISE 359AAV User Manual

Page 5: Installation positions, Location and clearances

Advertising
background image

5

Frozen Water Pipe Hazard

WATER DAMAGE TO PROPERTY HAZARD
Failure to follow this caution may result in property damage.
Do not leave your home unattended for long periods during

freezing weather without turning off water supply and

draining water pipes or otherwise protecting against the risk

of frozen pipes and resultant damage.

CAUTION

!

Your furnace is designed solely to provide a safe and comfortable

living environment. The furnace is NOT designed to ensure that

water pipes will not freeze. It is equipped with several safety

devices that are designed to turn the furnace off and prevent it

from restarting in the event of various potentially unsafe

conditions.
If your furnace remains off for an extended time, the pipes in

your home could freeze and burst, resulting in water damage.
If the structure will be unattended during cold weather you should

take these precautions.

1. Turn off the water supply to the structure and drain the wa-

ter lines if possible and add an antifreeze for potable water

to drain traps and toilet tanks. Open faucets in appropriate

areas.

--or--

2. Have someone check the structure frequently during cold

weather to make sure it is warm enough to prevent pipes

from freezing. Instruct them on a service agency to call to

provide service, if required.

--or--

3. Install a reliable remote sensing device that will notify

somebody of freezing conditions within the home.

Winter Shutdown

If you go away during the winter months and do not leave the

heat on in your home, the plastic transition box and the

condensate trap on the furnace must be protected from freeze

damage. (See Fig. 10 through Fig. 19 )

1. Disconnect the

5

/

8

″(16 mm)OD rubber hose from the vent

drain fitting that is located downstream of the combustion

blower. Insert a funnel into the hose and pour four(4)

ounces of sanitary type (RV) antifreeze into the condensate

trap. Reconnect the

5

/

8

″ (16 mm) OD rubber hose to the

stub on the vent drain fitting. Secure with the hose clamp.

2. Disconnect the

3

/

4

″ (19 mm) OD rubber hose from the

condensate trap. Insert a funnel into the hose and and pour

four(4) (ounces of sanitary type (RV) antifreeze into the

plastic Transition box. Squeeze the hose together near the

end and quickly reconnect the

3

/

4

″ (19 mm) OD rubber

hose to the stub on the condensate trap. Secure with the

hose clamp.

When you return home, your furnace will be ready to start, as it is

not necessary to drain the antifreeze from the furnace.

INSTALLATION

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or

death.
This furnace can NOT be common vented or connected to any

type B, BW or L vent or vent connector, nor to any portion of

a factory--built or masonry chimney. If this furnace is replacing

a previously common-vented furnace, it may be necessary to

resize the existing vent and chimney to prevent oversizing

problems

for

the

other

remaining appliance(s). See Venting and Combustion Air

Check in Gas Vent Installation section. This furnace MUST be

vented to the outside.

!

WARNING

Installation Positions

This furnace can be installed in an upflow, horizontal (either left

or right) or downflow airflow position. DO NOT install this

furnace on its back. For the upflow position, the return air

ductwork can be attached to either the left or right side panel

and/or the bottom. For horizontal and downflow positions, the

return air ductwork must be attached to the bottom. The return air

ductwork must never be attached to the back of the furnace.

Location and Clearances

1. Refer to Fig. 1 for typical installation and basic connect-

ing parts required. Refer to Fig. 4 for typical horizontal

direct vent installation and basic connecting parts required.

Supply and return air plenums and duct are also required.

2. If furnace is a replacement, it is usually best to install the

furnace where the old one was. Choose the location or

evaluate the existing location based upon the minimum

clearance and furnace dimensions (Fig. 2).

FROZEN AND BURST PIPE HAZARD
Failure to follow this caution may result in property damage.
Special precautions MUST be made is installing furnace in

an area which may drop below freezing. This can cause

improper operation or damage to equipment. If furnace

environment has the potential of freezing, the drain trap and

drain line must be protected. The use of electric heat tape or

RV antifreeze is recommended for these installations. (See

“Condensate Trap Freeze Protection Section”)

CAUTION

!

359AA