Caution, Warning, Ductwork and filter – Bryant 4-WAY MULTIPOISE 359AAV User Manual

Page 38: Thermostat, Optional equipment, Humidifier/electronic air cleaner, Furnace control, Furnace control fuse

Advertising
background image

38

5. Move J--Box to alternate location and attach using two self

tapping screws from bag.

6. Apply two hole plugs from bag at left J--Box location.

Thermostat

Thermostat location has an important effect on the operation of

the unit. Follow instructions included with thermostat for correct

mounting and wiring.
Low voltage connections to furnace must be made on terminal

board of furnace control.
Heat anticipator setting will need to be measured if 24VAC

humidifier is installed. Measure current in series from R to W at

the thermostat. Be sure 24VAC humidifier is wired up to control.

Allow furnace to operate for 2 minutes before recording the AC

amperage reading. Set anticipator on thermostat to recorded

value.

Optional Equipment

All wiring from furnace to optional equipment MUST conform to

local codes or, in the absence of local codes with the latest edition

of The National Electric Code, ANSI NFPA 70 and/or The

Canadian Electric Code CSA C22.1. Install wiring in accordance

with manufacturer’s instructions. The wiring MUST have a

minimum temperature rating of 105° C.

Humidifier/Electronic Air Cleaner

The furnace is wired for humidifier and/or electronic air cleaner

connection.

REDUCED FURNACE LIFE HAZARD
Failure to follow this caution may result in reduced furnace

life.
Do NOT exceed 115V/1.0 amp. maximum current load for

both the EAC terminal and the HUM terminal combined.

CAUTION

!

HUMIDIFIER -- The 24V HUM is energized when the pressure

switch closes on a call for heat. The 115V HUM (called HUM on

Control) is energized when the inducer is energized.
ELECTRONIC AIR CLEANER -- EAC is energized when there

is a blower speed call, except is NOT energized when blower

operates in the hard--wired continuous fan mode.

Furnace Control

The furnace control is preset at the factory with a fixed blower

ON delay of 30 seconds in the heating mode. The blower OFF

timing is preset at 140 seconds. If desired, the fan OFF delay can

be reset to obtain the longest delay times while still maintaining

comfort levels. See “Furnace Wiring Diagram” .

NOTE: Junction Box can be
mounted to either the left or right
side.

Models may
have 1 or 2
pressure
switches

NOTE: 115 VAC/60Hz/single--phase
Operating voltage range*: 127 VAC max, 104 VAC min.

* Permissible limits of voltage at which unit will operate satisfactorily

115V. 60 Hz

W

W

W

Low Voltage
Terminal Board

R

R

BK

Ground

Connection

Box

G

HO

T

NEUT

.

G

G

Y

G

O

N

O

FF

Representative drawing only, some models may vary in appearance.

A07726

Fig. 39 -- Electrical Connections

Furnace Control Fuse

The 24V circuit contains a 5--amp, automotive--type fuse located

on furnace control. (See Fig. 40.) Any electrical shorts of 24V

wiring during installation, service, or maintenance may cause

fuse to blow. If fuse replacement is required, use only a fuse of

identical size (5 amp.)

Blower Off
Delay Jumper

FUSE

Diagnostic Light

24 VAC
HUM

115 VAC
HUM

EAC

A07727

Fig. 40 -- Control Board

DUCTWORK AND FILTER

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or

death.
Do NOT draw return air from inside a closet or utility room

where furnace is located. Return air duct MUST be sealed to

furnace casing.

!

WARNING

359AA

V