7 Configuration
38
Decimal point
DECPOINT
0
1
2
3
7
no digit after the decimal point
one digit after the decimal point
two digits after the decimal point
three digits after the decimal point
System point
This setting is only valid for the display of
measurement value of analog input 1 or 2!
(Adjustment in the setup program under
Display/Operation -> Display -> Channel name)
Correction
value KTY at
25°C
(Setup)
0…
2000 …
4000
Resistance in ohms at 25°C/77°F for
„KTY 11-6“ linearisation
Adjustment only possible in the setup program:
-> Analog inputs -> Analog input 1 or 2
➔ INPUT1 (analog input 1) ➔
➔ INPUT2 (analog input 2) ➔
Parameter
Value/
Selection
Description
Factory settings are shown bold.
➔ INPUT (analog inputs general) ➔
Parameter
Value/
Selection
Description
Temperature
unit
Temperature unit
UNIT
0
1
deg. Celsius
deg. Fahrenheit
Unit for temperature values
Mains
frequency
Mains frequency
FREQUENC
0
1
50Hz
60Hz
Adaptation of the conversion time of the input
circuitry to the supply frequency
Sampling cycle
time
Sampling cycle
time
CYCLE-t
0
1
2
3
50ms
90ms
150ms
250ms
Factory settings are shown bold.