6commissioning of the profinet – Lenze PROFINET Controller-based Automation User Manual

Page 25

Advertising
background image

Lenze · Controller-based Automation · PROFINET® Communication Manual · DMS 1.2 EN · 04/2014 · TD17

25

6

Commissioning of the PROFINET

6.2

The commissioning steps in detail

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4. Go to the Standard project dialog window and select the target system in the

Device

selection field:

• Lenze Logic Controller

For controlling inverters which perform simple motions, do not have any motion

functionality or are controlled via pure PLC functionalities.

• Lenze Motion Controller

Only if an additional Motion bus with EtherCAT is used (see

Mixed operation PROFINET

with EtherCAT

( 32)

)

Further optional project settings

Selection of the Lenze control technology release version

Selection of the compiler version

Selection of the programming language:

• Sequential function chart (SFC)
• Instruction list (IL)
• Continuous function chart (CFC)
• Function block diagram (FBD)
• Ladder diagram (LD)
• Structured text (ST)

5. Confirm the selection by clicking OK.