3 terminology used, Terminology used, 1about this documentation – Lenze PROFINET Controller-based Automation User Manual

Page 6

Advertising
background image

1

About this documentation

1.3

Terminology used

6

Lenze · Controller-based Automation · PROFINET® Communication Manual · DMS 1.2 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

1.3

Terminology used

Term

Meaning

CL-RPC

Connectionless Remote Procedure Call

Code

Parameter for parameterising or monitoring the field device. The term is also

referred to as "index" in common usage.

Controller

The controller is the central component of the automation system which

controls the Logic and Motion functionalities (by means of the runtime

software).

The controller communicates with the field devices via the fieldbus.

Engineering PC

The Engineering PC and the Engineering tools installed serve to configure and

parameterise the system.

The Engineering PC communicates with the controller via Ethernet.

Engineering tools

Lenze software solutions for simply engineering in all phases:

• »EASY Starter«

• »Engineer«

• »PLC Designer«

• »WebConfig«

• »VisiWinNET®«

• »IPC Backup & Restore«

Lenze Engineering tools ( 17)

Siemens software for programming and configuring Siemens SIMATIC S7 PLC:

• »STEP7«

EtherCAT® (Ethernet for Controller and Automation Technology) is an Ethernet-

based fieldbus system which fulfils the application profile for industrial real-

time systems.

EtherCAT® is a registered trademark and patented technology, licensed by

Beckhoff Automation GmbH, Germany.

Fieldbus stations

Controller (PLC) and inverter integrated into the bus system (PROFINET)

Field device
GSDML file

A GSDML file described the properties of a field device.

It is described with the XML-based language GSDML (General Station

Description Markup Language).

I/O device

PROFINET slave

I/O master

PROFINET master

The I/O master takes over the master function for data communication of the

decentralised field devices. The I/O master is usually the communication

interface of a PLC.

Inverter

Generic term for Lenze frequency inverters, Servo Inverters

PDO

Process Data Object

PLC

Programmable Logic Controller

(German designation: SPS - Speicherprogrammierbare Steuerung)
PROFINET® (Process Field Network) is a real-time capable fieldbus system based

on Ethernet.

PROFINET® is a registered trademark and patented technology licensed by the

PROFIBUS & PROFINET International (PI) user organisation.

RT over UDP

Real Time over User Datagram Protocol

Subcode

If a code contains several parameters, they are stored in so-called "subcodes".

This manual uses a slash "/" as a separator between code and subcode

(e.g. "C00118/3").

In normal usage, the term is also referred to as "Subindex".