Parameter values in the octet string format (VO)
The LECOM-A/B protocol includes the octet string format (VO) with which it is possible to transfer data blocks.
The character sequence corresponds to the filing in the memory (ascending order), i.e. the character transmitted first
is the data block nibble with the lowest address. The data structure of the data block corresponds to the Intel-memory
format with the following definition:
BYTE:

1st high nibble

2nd low nibble

WORD:

1st high BYTE

2nd low BYTE

DWORD:

1st high WORD

2nd low WORD

5.5

Block-Check Character (BCC)

The block-check character (BCC) is used to store the transmitted data and is generated according to DIN 66219 (chapter 3).
Because of the program, the block-check character is generated by an XOR link from the following digits of the SEND
telegram:
• it starts with the character directly after the STX control character
• it ends directly after the ETX control character

- BCC can accept the value 00 ... FF

hex

.

EOT

AD1

AD2

STX

C1

C2

V1

O

Vn

ETX

BCC

BCC

or with expanded addressing:

STX

“!”

CH1

CH2

O

SC2

ETX

BCC

BCC