Mechanical installation

Mounting steps

3

l

36

EDK94ZPM113 DE/EN/FR/ES/IT 4.0

3.3

Mounting steps

Mounting procedure:
1. Prepare M5 threaded holes on the mounting plate according to the

mounting grid.

–

Start on the left with the mounting backplane of DC−supply module
E94AZPNxxxx or with DC input module E94AZEX100.

–

Install the axis modules from the left to the right with decreasing rated
power.

–

Axis modules E94AMxE0324 and installation backplane E94AZPM0324
can only be connected directly to each other! A use with another device
or installation backplane of size 3 is not permissible and is prevented
through a plug protection.

2. Screw the mounting backplane onto the mounting plate. Do not yet

tighten the screws.

–

Use M5 screw and washer assembly or M5 hexagon socket screws with
washer.

–

The screw joint in the installation backplane may not jut out more than
7 mm.

3. Align all components.

)

Note!

The installation backplane fixing screws are not tightened until the
busbars are connected.