Mechanical installation

Mounting steps

3

l

36

EDK94ZPM113 DE/EN/FR/ES/IT 4.0

3.3

Mounting steps

Mounting procedure:
1. Prepare M5 threaded holes on the mounting plate according to the

mounting grid.

Start on the left with the mounting backplane of DC−supply module
E94AZPNxxxx or with DC input module E94AZEX100.

Install the axis modules from the left to the right with decreasing rated
power.

Axis modules E94AMxE0324 and installation backplane E94AZPM0324
can only be connected directly to each other! A use with another device
or installation backplane of size 3 is not permissible and is prevented
through a plug protection.

2. Screw the mounting backplane onto the mounting plate. Do not yet

tighten the screws.

Use M5 screw and washer assembly or M5 hexagon socket screws with
washer.

The screw joint in the installation backplane may not jut out more than
7 mm.

3. Align all components.

)

Note!

The installation backplane fixing screws are not tightened until the
busbars are connected.