Example circuit, Electrical installation – Lenze E94AZPM User Manual
Page 39
![background image](/manuals/565814/39/background.png)
Electrical installation
Example circuit
l
39
EDK94ZPM113 DE/EN/FR/ES/IT 4.0
4.2
Example circuit
E94AMxExxxx
X100
V
X105
X107
X3
X106
M
3~
R
Y
2
7
+
-
EYF...
X7
E94AZPxxxxx
T1 T2
U
W
BD1 BD2
+
-
A1-
A1+
+UG -UG
+
-
RFR
X5
GI
RFR
+
-
X109
X109
X109
X109
X110
X110
X110
X110
-UG
+UG
0
1
J
X2
24E
SB
GE
+
-
+
+
SSP94PSP31
Fig. 4−1
Example circuit of installation backplane and standard device
E94AMxExxxx
9400 Multi Drive servo axis module
E94AZPxxxxx
Installation backplane
0
DC power supply module or DC feeding point or axis module
1
Next axis module
"
HF shield termination through large−surface connection to functional
earth
EYF...
System cable for resolver feedback
RFR
Controller enable
R
Resolver
Y
Motor holding brake (connected to optional motor brake control)
Speed setpoint selection via analog input 1 (−10 ... 0 ... +10 V)
Voltage source for the motor holding brake
24−V voltage source for the digital inputs according to IEC 61131−2
24−V voltage source for control electronics according to IEC 61131−2