Electrical installation – Lenze E94AZPM User Manual

Page 47

Advertising
background image

Electrical installation

Wiring

Terminal assignment

4

l

47

EDK94ZPM113 DE/EN/FR/ES/IT 4.0

Motor temperature monitoring

Terminal X106

Labelling

Description

T1
T2

Motor temperature monitoring with PTC element
(type−A sensor, switching performance according to
EN 60947−8 for type−A tripping units) or thermostat
(NC contact).

SSP940X106

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 5.3

PZ0

With wire end
ferrule

Motor brake control (optional)

,

Observe the notes in the Mounting Instructions on the motor brake
control.

Terminal X107

Labelling

Description

Connection of the motor holding brake

BD1
BD2

+ (Lenze: WH)
− (Lenze: BN)
E94AZHX0051: 24 V DC, max. 2.5 A
Observe correct polarity!

+ / −

Supply voltage for the motor holding brake
(18 ... 30 V DC)
Observe correct polarity!

SSP940X107

Terminal data

Max. conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 5.3

PZ0

With wire end
ferrule