General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approvals

M

File No. E210321

CCC

Protection of persons and equipment

Degree of protection

IEC/EN 60034−5

See nameplate

Degrees of protection only apply to horizontal installation

All unused plug−in connections must be sealed with
protective caps or dummy connectors.

Thermal class

F (155 °C)
IEC/EN 60034−1

Exceedance of the temperature limit weakens or destroys the
insulation

Permissible voltage

According to limiting curve A of the pulse voltage from
IEC / TS 60034−25 (image 14)

EMC

Noise emission

IEC/EN 61800−3

Depending on the controller, see documentation for the
controller.

Noise immunity

Operating conditions

Ambient conditions

Climatic

Transport

IEC/EN 60721−3−2

2K3 (−20 ... +70 °C)

Storage

IEC/EN 60721−3−1

1K3 (−20 ... +60 °C)

< 3 months

1K3 (−20 ... +40 °C)

> 3 months

Operation

IEC/EN 60721−3−3

Without brake −15 °C ... +40 °C
With brake −10 °C ... +40 °C

Without power reduction

> +40 °C

With power reduction see,
catalogue

Site altitude

< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue

Humidity

Average relative humidity 85 %, without condensation

Electrical

Motor connection dependent on the
controller

See inverter instructions

Length of motor cable

Length of cable for speed feedback

Mechanical

IEC/EN60721−3−3

3M6