background image

Mechanical installation

Mounting
Preparation

5

l

30

BA 12.0023−EN 7.0

5.4

Mounting

5.4.1

Preparation

(

Stop!

Thoroughly remove anticorrosion agents from output shafts and flange faces.

Correcting the oil quantity

If the oil quantity has been increased in the gearbox for long−term storage (see chapter
5.2), the oil must be completely drained and then filled in again for the corresponding
mounting position. The following steps must be observed:

1. Place receptacle under oil drain plug.

2. Remove ventilation / oil filler plug.

3. Completely drain lubricant.

4. Screw in oil drain plug.

5. Fill in oil quantity for the corresponding mounting position (

^ 66).

6. Screw in ventilation / oil filler plug.

Condensation drain hole

)

Note!

Lenze delivers motors with condensation drain holes with sealed condensation
drain holes. The holes are sealed with a plastic plug or a plug screw. This does
not impair the enclosure and the motor is protected against ingress of foreign
particles during transport and operation. For further information, please see
chapter 8.2.1.