Mechanical installation

Storage

5

l

28

BA 12.0023−EN 7.0

5.2

Storage

If you do not install the gearbox immediately, ensure appropriate conditions of storage.

ƒ

Generally
– Store gearbox in dry, clean (dust−free) and sunlight−protected indoor rooms.
– The storage location must be free of vibration and shocks (V

eff

< 0.2 mm/s) to

avoid roller bearing downtime damage.

– Temperature changes with condensate formation must be avoided.
– Do not activate breather element to prevent air exchange with ambient air.

ƒ

Up to one year:
– Store the gearbox with breather such that the breather screw is located at the top.
– Shafts and bright surfaces are delivered with protection against corrosion. Spots

with defective corrosion protection must be re−treated.

– On motors with condensation drain holes (option), the plug screw must be

removed (see chapter 5.4.1).

ƒ

Over one year, up to two years:
– Before storage, shafts and bright surfaces must be provided with a long−term

anticorrosive agent (e.g. Anticorit BW 366 from the company Fuchs).

– Set up gearbox in mounting position A.
– Fill gearbox with oil grade filled in (see nameplate) up to the top breather / oil

bore. Then mount plug screw or breather element (do not activate) again.

Advertising