3 connection of the speed measuring unit, Connection of the speed measuring unit, Installation – Lenze SIMPLABELT Compact Units User Manual

Page 17

Advertising
background image

Installation

17

L

BA S’belt KE EN 1.0

F1

Fuse

K1, K2

Combined contactor relay for phase reversion

(CW or CCW rotation of the adjusting motor)

M1

Remote-control motor

Q1

Main switch

Q2

Motor circuit breaker

S1

Momentary-contact switch “faster”

S2

Momentary-contact switch “slower”

S3

Limit switch (highest speed limit)

S4

Limit speed (lowest speed limit)

Drive motor

Control phase of drive motor

faster

slower

K11.0252

Fig. 3

Connection diagram for the electrical remote control

4.3.3

Connection of the speed measuring unit

You can select the speed measuring units. They all can be retrofitted. The speed measuring units
are delivered with connection cables. They are connected according to the user’s application or to
the requirements of the Lenze display units.

Three-phase AC tacho with rectification

The three-phase AC tacho with rectification generates a voltage which depends on the speed and
the input resistance of the evaluating unit. The generated voltage can be evaluated via a
superimposed control or Lenze display units.

Suitable Lenze display units:
Analog voltmeter VSC 96 (approx. 5000

)

Digital voltmeter Fdi 635-F (> 100 k

)

2

5

4

3

1

6

7

K11.0340

1

Complete tacho

2

Cover

3

Tightenning screw

4

Sealing washer

5

Allen screw

6

Stator (must be adjusted concentrically, gap “a”

must not change)

7

Cable, 1m

Fig. 4

Three-phase AC tacho with rectification

Show/Hide Bookmarks