Installation

18

L

BA S’belt KE EN 1.0

Fig. 5

Output voltage of the three-phase AC tacho with rectification as a function of the speed and the input resistance of the
display unit

Pulse recorder

The contactless speed measuring works with a rotating punched disk and a fixed pulse recorder.
In connection with a NAMUR input the pulse recorder generates a digital signal.

Suitable Lenze display units:
Analog voltmeter VSC 96 (approx. 5000

) with digital-to-analog converter

Digital display unit ELTA 2000 A

1

Pulse recorder

2

Punched disk

3

Fixing screw

4

Cover

K11.0249/1

Fig. 6

Pulse recorder

Technical data:

Housing

Stainless steel

Connection cable

2.5 m PVC cable 2 x 0.14mm max. 300 m should be connected

Control circuit

DIN 19234 or NAMUR

Auxiliary power/rated value

8.2 V ” 0.5 V / R

i

= 1 k

” 50

Signal voltage

> 1,2 V

ss