7 troubleshooting and fault elimination, 8 waste disposal, Troubleshooting and fault elimination – Lenze SIMPLABELT Compact Units User Manual

Page 26: 7troubleshooting and fault elimination

Advertising
background image

Troubleshooting and fault elimination

26

L

BA S’belt KE EN 1.0

7

Troubleshooting and fault elimination

If any disturbance should occur during operation of the drive system, please check the possible
causes using the following table. If the fault cannot be eliminated by means of one of the listed
measures, please contact Lenze Service.

Fault

Possible cause

Remedy

Drive does not start

No or faulty connection of main motor

Check motor connection

Clearly audible running noise

V-belt runs on hub base, wrong adjustment of speed
limit

Correct adjustment of speed limit

Speeds indicated on the nameplate cannot be
reached

Wrong adjustment of speed limit

Correct adjustment of speed limit

reached

Wrong V-belt

Use V-belt which corresponds to compact unit

Position indicated on handwheel does not correspond
to output speed

Wrong assembly of position indicator

Assemble position indicator at adjustment of max.
output speed

Motor of electric remotecontrol does not rotate

Adjustment spindle is stalling

To do this, remove the plastic plug at the rear side of
the adjustment motor.Loosen via the central thread
of the motor shaft.

Show/Hide Bookmarks