8 diagnostics, Led status displays, Diagnostics – Lenze E82ZAFLC001 User Manual

Page 54: 8diagnostics

Advertising
background image

8

Diagnostics

LED status displays

EDK82ZAFLC−001 DE/EN/FR 5.0

54

l

H1_Diagnose−statusanzeige

8

Diagnostics

LED status displays

Pos.

Colour

Status

Description

1

yellow

off

l

No communication with the host system

l

The function module is not supplied with voltage.

blinking

Communication via the function module to the host system has
been established.

2

green

off

l

The function module is not supplied with voltage.

l

The standard device and/or the external voltage supply is/are
switched off.

blinking

The function module is supplied with voltage but is not connected to
the standard device.
Possible causes:

l

The standard device is switched off.

l

The standard device is in the initialisation phase.

l

The standard device is not available.

on

The function module is supplied with voltage and is connected to the
standard device.

1

+

2

yellow /
green

blinking

Internal error of the function module

Advertising