Commissioning
Possible settings via the front DIP switches
EDKMF2113 DE/EN/FR 5.1
62
l
H1inbet−Merker_hidden statusanzeige
Setting the number of process data words (PCD)
)
Note!
ƒ
Impermissible settings are indicated by the yellow LED (communication)
(
^ 69).
ƒ
The current switch position of S1 ... S4 for the number of process data
words (PCD) can be displayed under code C1915.
ON
OFF
OPEN
1 2 3 4
5 6 7 8
Length
PD
2113IBU005
PCD
Switches
Max. number of parameter data
words (PCP)
S1
S2
S3
S4
1
OFF
OFF
OFF
ON
4
2
OFF
OFF
ON
OFF
3
OFF
OFF
ON
ON
4
OFF
ON
OFF
OFF
5
OFF
ON
OFF
ON
6
OFF
ON
ON
OFF
7
OFF
ON
ON
ON
2
8
ON
OFF
OFF
OFF
9
ON
OFF
OFF
ON
1
10
ON
OFF
ON
OFF
0