6 technical data, General data and operating conditions, Technical data – Lenze EMF2113IB User Manual
Page 70: 6technical data
Advertising
![background image](/manuals/565915/70/background.png)
6
Technical data
General data and operating conditions
EDKMF2113 DE/EN/FR 5.1
70
l
H1_Daten−AlleMaßeInMM
6
Technical data
General data and operating conditions
Field
Values
Communication media
RS485
Network topology
Ring
Communication profile
PCP 2.0
Drive profile
DRIVECOM profile 21
INTERBUS node
Slave
Baud rate
l
500 kbits/s
l
2 Mbits/s
External voltage supply
Values
"+"
U = 24 V DC (21.6 V − 0% ... 26.4 V + 0 %)
I = 120 mA
"−"
Reference potential for external voltage supply
Ambient conditions
Climatic conditions
Storage 1 K3 to IEC/EN 60721−3−1
− 25 °C ... + 60 °C
Transport 2 K3 to IEC/EN 60721−3−2
− 25 °C ... + 70 °C
Operation 3 K3 to IEC/EN 60721−3−3
0 °C ... + 55 °C
Degree of pollution
2 to IEC/EN 61800−5−1
Enclosure
IP20
Advertising