Commissioning

Status display

5

EDKMF2113 DE/EN/FR 5.1

69

l

H1inbet−Merker_hidden statusanzeige

Status display

LED

Description

Pos.

Colour

Condition

0

green

on

Communication module is supplied with voltage and is
connected to the basic device.

off

Communication module is not supplied with voltage. Basic device
or external voltage supply is switched off.

blinking

Communication module is supplied with voltage, but is (still) not
connected to the basic device because

l

the communication module has not been correctly attached
to the basic device

l

it is not yet possible to transfer data from/to the basic device
(e.g. basic device in the initialisation phase).

1

yellow

on

Communication module is being initialised,
inactive INTERBUS communication of the master

off

Communication module is not yet initialised.

blinking

Active INTERBUS communication

l

SLOW (1 Hz): process data and PCP communication

l

FAST (4 Hz): only process data

l

VERY FAST (8 Hz)
– Indicates impermissible settings:

Data word sum: PD + PCP > 10 or number of process data
words: PD = 0.

– The communication module continues internally with the

following values: PD = 2 and PCP = 1

2

red /
green

Red and green drive LEDs indicate the operating status of the
82XX, 8200 vector, 93XX, Servo PLC 9300 and Drive PLC basic
device (see Operating Instructions for the basic device)