5

Commissioning

Initial switch−on

EDKMF2113 DE/EN/FR 5.1

68

l

H1inbet−Merker_hidden statusanzeige

Initial switch−on

1. The communication module must be attached to the controller (

^ 47).

2. Switch on the controller and, if required, the separate voltage supply for the

communication module (

^ 49).

3. Check communication module signals:

– The green bus LED indicates the operating status according to the description

under pos.

0 (^ 69).

– The yellow bus LED indicates the communication status according to the

description under pos.

1 (^ 69).

– Quick blinking (8 Hz) is the reaction of the yellow bus LED to impermissible

settings.

4. You can now communicate with the drive.

)

Note!

PCP communication

ƒ

With a PCP communication the controller parameters can only be accessed
after having executed the PCP service "Initiate". After this, the controller
parameters can be accessed with the PCP services "Read" and "Write".

ƒ

For a detailed description, please see the INTERBUS Communication
Manual.

LEDs at the front of the communication module

Please see the notes for the status display (

^ 69).