Technical data

Protective insulation

6

EDKMF2113 DE/EN/FR 5.1

73

l

H1_Daten−AlleMaßeInMM

Protocol data

Field

Values

Maximum number of
controllers

Dependent on INTERBUS master (e.g. Phoenix Contact G4 master).
For the following data, always the smaller value applies dependent
on the fact, whether PCP communication is available or not:

l

with PCP communication:

62 or

l

without PCP communication:

256/number of PD

Process data words (PD)

1 ... 10 (selectable)

Lenze setting: 2 words

Parameter data words (PCP)

0, 1, 2, 4

Lenze setting: 1 word

Maximum number of data
words

As a maximum, the data word sum (PD + PCP) is to amount to 10
words.

INTERBUS ID
(module ID)

Module ID for set length

3

= 0x03

PCP, 0 words

227

= 0xE3

PCP, 1 word

224

= 0xE0

PCP, 2 words

225

= 0xE1

PCP, 4 words

Maximum PDU length

64 bytes

Supported PCP services

Initiate, Abort, Status, Identify, Get−0V−long, Read, Write