4 technical data, General data, Operating conditions – Lenze E82ZAFUC010 User Manual

Page 50: Technical data, 4technical data

Advertising
background image

4

Technical data

General data

EDK82ZAFUC010 DE/EN/FR 4.0

50

l

H1_Daten−IP20

4

Technical data

General data

Field

Values

Order designation

E82ZAFUC010

Communication profile

CANopen, DS301 V4.02

Communication medium

DIN ISO 11898

Network topology

Line terminated at both ends with 120

W

resistor

Max. number of nodes

Max. 127 (with repeater)

Max. possible number of
nodes per segment

l

For E82ZAFUC010: 106 (max.)

l

In the case of different nodes:
see notes for mixed operation

^ 59

CANopen nodes

Slave

Baud rate [kbps]

10, 20, 50, 125, 250, 500, 1000

Process data words

1 ... 12 words

Operating conditions

Ambient conditions

Climate

Storage

IEC/EN 60721−3−1

1K3 (−25 to +60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 to +70 °C)

Operation

Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).

Pollution

EN 61800−5−1

Degree of pollution 2

Degree of protection

IP20 (protection against accidental contact according to NEMA 250 type 1)

Advertising