Cable cross-sections and screw-tightening torques, Cable cross−sections and screw−tightening torques, 6electrical installation – Lenze E82ZAFUC010 User Manual

Page 64

Advertising
background image

6

Electrical installation

Cable cross−sections and screw−tightening torques

EDK82ZAFUC010 DE/EN/FR 4.0

64

l

H2_LtgQuer+AnzMom−Steckerleiste_Federkraft

Cable cross−sections and screw−tightening torques

Field

Values

Electrical connection

Plug connector with double screw connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Tightening torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)

Stripping length

10 mm

Field

Values

Electrical connection

2−pin plug connector with spring connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule
1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve
1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve
1.5 mm

2

(AWG 16)

Stripping length

9 mm