Drive control & communication, 1 abbreviations, 11 rg-mcmod – Lenze MC Series Drives User Manual

Page 15

Advertising
background image

11

RG-MCMOD

Drive Control & Communication

ACT# (HEX

representation)

REGISTER NAME

R/W/RS

MESSAGE

MIN

MAX

UNITS

[NOTE]

or

Section

41 (29)

Local PID Command
(MC1000 w/PID, MC3000)

R

SA

03

00

29

00

01

CRCH

CRCL

Refer to Section 5.8

RS

SA

03

02

DH

DL

CRCH

CRCL

W

SA

06

00

29

DH

DL

CRCH

CRCL

RS

SA

06

00

29

DH

DL

CRCH

CRCL

48 (30)

Unlock Commands

W

SA

06

00

30

DH

DL

CRCH

CRCL

0

9999

None

5.10

RS

SA

06

00

30

DH

DL

CRCH

CRCL

49 (31)

Unlock Parameters

W

SA

06

00

31

DH

DL

CRCH

CRCL

0

9999

None

5.11

RS

SA

06

00

31

DH

DL

CRCH

CRCL

50 (32)

Register Version

R

SA

03

00

32

00

01

CRCH

CRCL

0

65535

None

5.12

RS

SA

03

02

DH

DL

CRCH

CRCL

5.1 Abbreviations

Table 7 lists the abbreviations used in Table 6 MCH Drive Control Registers:

Table 7: Abbreviations

Abbreviation

Description

R

Read

W

Write

RS

Response

SA

Slave Address (typically 01 through F7 hex)

CRCH

CRC High byte

CRCL

CRC Low byte

DH

Data High byte

DL

Data Low byte

ACT#

AC Tech Register # (Modbus Register numbers are 1 larger)