Parameter setting

Parameter setting with the XT EMZ9371BC keypad
Display elements and function keys

3

l

22

EDKVF93−01 EN 3.0

Displays

0 Status displays of standard device

Display

Meaning

Explanation

d

Ready for operation

c

Pulse inhibit is active

Power outputs are inhibited

b

The set current limit is exceeded in motor or
generator mode

B

Speed controller 1 in the limitation

Drive is torque−controlled
(Only active for operation with standard
devices of the 9300 series)

A

Active fault

1 Acceptance of the parameters

Display

Meaning

Explanation

p

Parameter is accepted immediately

Standard device operates immediately with
the new parameter value

SHPRG

p

Parameter must be acknowledged with

T V Standard device operates with the new

parameter value after being acknowledged

SHPRG

Parameter must be acknowledged in case of
controller inhibit

T V

Standard device operates with the new
parameter value after the controller is
enabled again

None

Display parameter

Change is not possible

2 Active level

Display

Meaning

Explanation

Menu

Menu level is active

Select main menu and submenus

Code

Code level is active

Select codes and subcodes

Para

Parameter level is active

Change parameters in the codes or
subcodes

None

Operating level is active

Display operating parameters

3 Short text

Display

Meaning

Explanation

alphanumeric
al

Contents of the menus, meaning of the codes
and parameters

In the operating level display of C0004 in % and
the active fault

4 Number

Active level

Meaning

Explanation

Menu level

Menu number

Display is only active for operation with
standard devices of the 8200 vector or 8200
motec series

Code level

Four−digit code number

5 Number

Active level

Meaning

Explanation

Menu level

Submenu number

Display is only active for operation with
standard devices of the 8200 vector or 8200
motec series

Code level

Two−digit subcode number

6 Parameter value

Parameter value with unit

7 Cursor

In the parameter level, the digit above the cursor can be directly changed

8 Function keys

For description see the following table