Troubleshooting and fault elimination

Troubleshooting

Fault analysis with the history buffer

4

l

35

EDKVF93−01 EN 3.0

4.2.2

Fault analysis with the history buffer

Retracing faults

Faults can be retraced via the history buffer. Fault messages are stored in the 8 memory
locations in the order of their appearance.

The memory locations can be retrieved via codes.

Structure of the history buffer

Code

Memory location

Entry

Note

C0168/1 C0169/1 C0170/1 Memory location 1

Active fault

If the fault is no longer pending or has been
acknowledged:

l

The contents of the memory locations
1 ... 7 are shifted "up" to the next memory
location.

l

The content of memory location 8 is
deleted from the history buffer and cannot
be retrieved anymore.

l

Memory location 1 is deleted (= no active
fault).

C0168/2 C0169/2 C0170/2 Memory location 2

Last fault

C0168/3 C0169/3 C0170/3 Memory location 3

Last but one fault

C0168/4 C0169/4 C0170/4 Memory location 4

Last but two fault

C0168/5 C0169/5 C0170/5 Memory location 5

Last but three fault

C0168/6 C0169/6 C0170/6 Memory location 6

Last but four fault

C0168/7 C0169/7 C0170/7 Memory location 7

Last but five fault

C0168/8 C0169/8 C0170/8 Memory location 8

Last but six fault

Explanations regarding the codes

C0168

Fault indication and response

l

The entry is effected as a LECOM error number

l

If several faults with different responses occur at the same time:
– Only the fault with the highest priority response is entered (1. TRIP, 2. message,

3. warning).

l

If several faults with the same response (e.g. 2 messages) occur at the same time:
– Only the fault which occurred first is entered.

C0169

Time of fault occurence

l

The reference time is provided by the power−on time meter (C0179).

l

If the same fault occurs several times in succession, only the time of the last occurrence
is stored.

C0170

Fault frequency

l

Only the time of the last occurrence is stored.

Clear history buffer

Set C0167 = 1 to clear the history buffer.