Product description

Variants
MC−PNC, MC−PND

3

l

22

BA_MC−Card EN 1.0

MC−PND (device)

I/O data

l

Configurable up to max. 1024 bytes input

l

Configurable up to max. 1024 bytes output

Communication

l

PROFINET IO−RT
– VLAN and priority tagging
– cyclic and acyclic

Functions

l

Cyclic process data

l

Acyclic read and write requests

l

Process and diagnostic alarm: 200 bytes

l

DCP

l

Context management via CLRPC

l

Generic diagnostics, channel diagnostics, extended
channel diagnostics: 200 bytes

l

Comparison of the setpoints / actual values of the
configuration

Special features

l

Maximum number of modules: 244

l

Maximum number of submodules: 1

l

No support for
– RT over UDP
– Multicast communication

l

Only one device instance is supported

¸

O

Warnings!

Use only together with appropriate cable connectors, provided with screws for
securement and secure connector to avoid loosening.
For use in controlled environment only.

¹

O

Warnings!

A utiliser exclusivement avec des connecteurs de câble à vis adaptés. Fixer les
connecteurs pour éviter toute déconnexion.
Destiné uniquement à des zones à environnement contrôlé.