Drive control & communication, 3 drive size - register #21 – Lenze Tmd Series Drives Modbus Communications User Manual

Page 18

Advertising
background image

RG-TDMOD 14

Drive Control & Communication

NOTE 1 - Drive Control
• During each write to Register #1 only one bit should be set in the drive control word.
• If more than 1 bit is set, the drive responds to stop bit only.
• If stop bit is not set, but more than 1 bit is set, drive responds with exception 04.

NOTE 2 - Drive Family
• The QC and DL Series drives return 64 (40H)
• The MC Series drives return 65 (41H)
• The SC Series drives return 66 (42H)
• The MCH Series drives return 68 (44H)
• The

smd Series drives return 69 (45H)

• The TC Series drives return 70 (46H)
• The

Tmd Series drives return 71 (47H)

• The SMV Series drives return 72 (48H)

5.3 Drive Size - Register #21

Table 9 lists the

Tmd Series drives. Register 21 will contain the value in the "Size" column.

Table 9: Drive Size - Register #21

Size

kW

Voltage

Size

kW

Voltage

00

0.55

1/N/PE or 3/PE

230V

28

0.55

3/PE

400/480V

01

0.37

29

0.37

02

0.75

30

0.75

03

1.1

31

1.1

04

1.5

32

1.5

05

2.2

33

2.2

16

0.75

3/PE

230V

34

4.0

17

1.1

35

5.5

18

1.5

36

7.5

19

2.2

44

3.0

20

4.0

21

5.5

22

7.5

Advertising