Drive control & communication, 2 parameter list – Lenze Tmd Series Drives Modbus Communications User Manual

Page 25

Advertising
background image

21 RG-TDMOD

Drive Control & Communication

6.2 Parameter List

Parameter No.

1

Tmd Register #

(hexadecimal

representation)

Parameter Name

Range of Adjustment

Modbus value (decimal value)

Factory

Default

PV503

C01

51 (33H)

Setpoint and Control Source

Speed

Control

Program

0 Analog Terminal

Keypad

1 c40

Terminal

Keypad

2 Analog Terminal

LECOM

3 LECOM LECOM

LECOM

4 Analog

Terminal

Remote Keypad

5 c40

Terminal

Remote Keypad

6 Analog

Remote Keypad Remote Keypad

7 c40

Remote Keypad Remote Keypad

8 Analog Terminal

Modbus

9 c40

Terminal

Modbus

10 Analog Modbus

Modbus

11 c40

Modbus

Modbus

0

C02

52 (34H)

Load Lenze setting

0 No action/loading complete
1 Load 50Hz Lenze settings
2 Load 60Hz Lenze settings
3 Load OEM settings (if present)

0

CE1
CE2
CE3
CE4

53 (35H)
54 (36H)
55 (37H)
56 (38H)

Configuration
Digital Inputs
E1, E2, E3, E4

1 Activate fixed setpoint 1 (JOG1)
2 Activate fixed setpoint 2 (JOG2)
3 DC Braking (DCB)
4 Direction of Rotation
5 Quick Stop
6 CW Rotation
7 CCW Rotation
8 UP
9 DOWN
10 TRIP set
11 TRIP reset
12 Accel/decel 2

CE1 = 1
CE2 = 2
CE3 = 3
CE4 = 4

57 (39H)

Not Used

58 (3AH)

RESERVED

C09

59 (3BH)

Network Address

1 - 247

1

C10

60 (3CH)

Minimum Output Freq.

0 - 2400 (0.0 - 240 Hz)

0.0 Hz

C11

61 (3DH)

Maximum Output Freq.

75 - 2400 (7.5 - 240 Hz)

50.0 Hz

C12

62 (3EH)

Acceleration Time

0 - 9990 (0.0 - 999 sec)

5.0 sec

C13

63 (3FH)

Deceleration Time

0 - 9990 (0.0 - 999 sec)

5.0 sec

1 = The drive's programming code number; (2) = Two decimal places assumed