Table 5 describes the SCF Drive Control Registers in ascending order of AC Tech Register #. The HEX
representation is given in parenthesis next to the AC Tech Register # in the left-most column.

Table 5: SCF Drive Control Registers

AC Tech Register #

(HEX representation)

REGISTER NAME

R/W/RS

MESSAGE

MIN

MAX

UNITS

[NOTE]

or

Section

1 (01)

Drive Control

W

SA

06

00

01

DH

DL

CRC

Refer to Section 5.2

[1]

RS

SA

06

00

01

DH

DL

CRC

19 (13)

Drive Family

R

SA

03

00

13

00

01

CRC

Refer to Section 5.2

[2]

RS

SA

03

02

00

42

CRC

21 (15)

Drive Size

R

SA

03

00

15

00

01

CRC

Refer to Section 5.2

[3]

RS

SA

03

02

00

00

CRC

22 (16)

Drive H/W

R

SA

03

00

16

00

01

CRC

Refer to Section 5.3

RS

SA

03

02

DH

DL

CRC

24 (18)

Drive Status
(6 register read)
(reg. #24 to 29)

R

SA

03

00

18

00

06

CRC

Refer to Section 5.4

RS

SA

03

0C

D1H

D1L

D2H

D2L

D3H

D3L

D4H

D4L

D5H

D5L

D6H

D6L

CRC

24 (18)

Command Speed

R

SA

03

00

18

00

01

CRC

0

2400

0.1 Hz

[4a]

RS

SA

03

02

DH

DL

CRC

25 (19)

Actual Speed

R

SA

03

00

19

00

01

CRC

0

2400

0.1 Hz

[4b]

RS

SA

03

02

DH

DL

CRC

26 (1A)

Load (DH) /
Status (DL)

R

SA

03

00

1A

00

01

CRC

Refer to Section 5.4.2

[4c]

RS

SA

03

02

DH

DL

CRC

27 (1B)

Actual Rot. Direction (DH)/
Control Mode (DL)

R

SA

03

00

1B

00

01

CRC

Refer to Section 5.4.3/4

RS

SA

03

02

DH

DL

CRC

28 (1C)

Speed Source (DH)/
Auto/Manual (DL)

R

SA

03

00

1C

00

01

CRC

Refer to Section 5.4.5/6

RS

SA

03

02

DH

DL

CRC

29 (1D)

Fault (DH)/
Commanded Direction (DL)

R

SA

03

00

1D

00

01

CRC

Refer to Section 5.4.7/8

[4d]

RS

SA

03

02

DH

DL

CRC

30 (1E)

Motor Voltage

R

SA

03

00

1E

00

01

CRC

0

250

1%

5.5

RS

SA

03

02

DH

DL

CRC

40 (28)

Keypad Speed Command

R

SA

03

00

28

00

01

CRC

0

2400

0.1 Hz

5.6

RS

SA

03

02

DH

DL

CRC

W

SA

06

00

28

DH

DL

CRC

RS

SA

06

00

28

DH

DL

CRC

48 (30)

Unlock Commands

W

SA

06

00

30

DH

DL

CRC

0

9999

None

5.7

RS

SA

06

00

30

DH

DL

CRC

49 (31)

Unlock Parameters

W

SA

06

00

31

DH

DL

CRC

0

9999

None

5.8

RS

SA

06

00

31

DH

DL

CRC

50 (32)

Register Version

R

SA

03

00

32

00

01

CRC

0

65535

None

5.9