Drive control & communication – Lenze SCF Series Drives Modbus Communications User Manual

Page 20

Advertising
background image

RG-SFMOD 16

Drive Control & Communication

5.4.7 Present Fault - Registers #24 & 29

Table 15 lists the Present Fault (Register #24 byte D6H of Register #29 DH)

Table 15: Present Fault

Setting

Fault

Display

0

NO FAULT

1

OUTPUT (TRANSISTOR) FAULT

“OF”

2

HIGH DRIVE TEMPERATURE

“AF”

3

HIGH DC BUS VOLTAGE

“HF”

4

LOW DC BUS VOLTAGE

“LF”

5

THERMAL OVERLOAD

“PF”

CONTROL FAULT

“CF”

7

EXTERNAL

“EF”

8

OEM FAULT

“GF”

9

START ERROR

“UF”

10

INTERNAL1 (EPM)

“F1”

11

INTERNAL2

“F2”

12

INTERNAL3

“F3”

13

INTERNAL4

“F4”

14

INTERNAL5

“F5”

15

INTERNAL6

“F6”

16

INTERNAL7

“F7”

17

INTERNAL8

“F8”

18

INTERNAL9

“F9”

19

INTERNALo

“Fo”

20

SINGLE PHASE FAULT

“SF”

21

INCOMPATIBILITY FAULT

“cF”

22

DYNAMIC BRAKE OVERHEATED

“dF”

23

SERIAL LINK FAULT

“JF”

5.4.8 Commanded Rotational Direction - Registers #24 & 29

Table 16 lists the Commanded Rotational Direction (Register #24 byte D6L or Register #29 DL)

Table 16: Commanded Rotational Direction

Setting

Direction

0

FORWARD

1

REVERSE

NOTE 4d - Commanded Rotational Direction
Register NOT used on SCF drives prior to software version 48, revision 7 (4807) and
software version 57, revision 3 (5703).

Advertising