Drive control & communication, 2 parameter list – Lenze SCF Series Drives Modbus Communications User Manual

Page 23

Advertising
background image

19 RG-SFMOD

Drive Control & Communication

6.2 Parameter List

AC Tech
Register
Number
(hexadecimal
representation)

Parameter

1

Parameter Name

Range of Adjustment
Modbus value (decimal value)

Factory Default

51 (33H)

1

Line Voltage

01 - High
02 - Low

01 - High

52 (34H)

2

Carrier Frequency

01 - 4 kHz
02 - 6 kHz
03 - 8 kHz
04 - 10 kHz

02 - 6 kHz

53 (35H)

3

Start Method

01 - Normal
02 - Start on Power-up
03 - Start w/DC Brake
04 - Auto Restart w/DC Brake
05 - Flying Restart 1
06 - Flying Restart 2
07 - Flying Restart 3

01 - Normal

54 (36H)

4

Stop Method

01 - Coast
02 - Coast with DC Brake
03 - Ramp
04 - Ramp with DC Brake

01 - Coast

55 (37H)

5

Speed Source

01 - Keypad
02 - Preset #1
03 - 0-10 VDC
04 - 4-20 mA

01 - Keypad

56 (38H)

6

TB-14 OC Output

01 - None
02 - Run
03 - Fault
04 - Inverse Fault
05 - Fault Lockout
06 - At Set Speed
07 - Above Preset #3
08 - Current Limit
09 - Auto Speed (speed source via terminal strip)
10 - Reverse (rotation direction indication)

01 - None

7

Not Used

58 (3AH)

8

TB-30 Analog Output

01 - None
02 - 0-10 VDC Freq
03 - 2-10 VDC Freq
04 - 0-10 VDC %Load
05 - 2-10 VDC %Load

01 - None

59 (3BH)

9

TB-31 Analog Output

01 - None
02 - 0-10 VDC Load
03 - 2-10 VDC Load
04 - Dynamic Braking

01 - None

1

= Drive's programming parameter number