EXTENSION CORD LENGTH

Nameplate

Amperes

115V

25'

50'

75'

100'

150'

200'

250V

50'

100'

150'

200'

300'

400'

0 - 5

16

16

16

14

12

12

5.1 - 8

16

16

14

12

10

8.1 - 12

14

14

12

10

12.1 - 15

12

12

10

10

15.1 - 20

10

10

10

WARNING

Use of undersized extension cords result in low voltage to the motor that can result in motor burnout

and premature failure. MK Diamond warns that equipment returned to us showing signs of being run

in a low voltage condition, through the use of undersized extension cords,will be repaired or replaced

totally at the customer’s expense. There will be no warranty claim.

To choose the proper extension cord,

• Locate the length of extension cord needed in the table below.

• Once the proper length is found, move down the column to obtain the correct

AWG size required for that length of extension cord.