WARNING

FOR DUAL VOLTAGE MODELS ONLY ! The MK-2000 motor has 2 voltage

positions, 115v and 230v. Ensure the Voltage Adjustment Switch of the

MK-2000 motor is set for the voltage of the intended power source BEFORE

installing the MK-2000 Power cord.

(A)

Ensure the ON/OFF Switch is in

the OFF position

(B)

Verify or place the Voltage Ad-

justment Switch in the correct

voltage position.

(C)

Locate the correct power source for

the setting of the MK-2000 Voltage

Adjustment Switch.

(D)

Align, install and twist clockwise to

lock the polarized plug of the MK-2000

into the correct power source.

MK-2000 ELECTRIC SAW

OPERATION

PORTABLE GENERATOR

If using a portable generator to provide power, ensure the generator meets the following minimum

requirements:

8 KW 120/240 volts 66.7/33.3 amps Single Phase

DUAL VOLTAGE

CHANGING VOLTAGE SETTING FOR THE MK-2002

(A)

Remove the Voltage Change

Switch locking nut and bolt using

3/8" and 5/16" wrenches.

(B)

Move the Voltage Change Switch

to the desired voltage setting.

(B)

Reinstall the locking bolt and

replace the nut.

Perform the following steps to change voltage setting between 115V and 230V.

CAUTION

The power must be removed from the saw before changing the voltage setting.